Powder

categorie prodotti

Poweder Dosing Machinery - Micro & Macro Dosing / Dual Chamber Systems

The alternate motion powder dosing machines have been designed and manufactured to meet the high quality standards required by the pharmaceutical industry and the relevant regulations.
All parts in contact with the product are manufactured in FDA-approved material and are supplied together with the relevant certificates. They have been designed in such a way to make them easy to remove, easy to inspect and quickly cleanable.

The Siempharma powder dosing machines feature a flexible configuration; they can be equipped with a single or double dosing head and with closing heads able to handle every type of caps used in the pharmaceutical packages (child-proof, pilfer proof, dosing cup…). The machines have been designed in compliance with GMP standards and particular attention has been paid to ergonomics in order to maintain visual control of all stages of the process and to ensure easy access to all parts of the unit.
The dosage is performed by means of a volumetric screw feeder made of AISI 316L, with a servomotor ensuring perfect control and possibility to set speed and time, via operator panel, according to the product type, thus ensuring high accuracy of dosage.
The dosage parameters can be set, saved and stored via the operator panel to be made immediately available in the event of a production change; this ensures the standardization of the process resulting in the achievement of high levels of efficiency and quality.
In addition the machine can be equipped with a net weight control system which measures the weight of the empty bottle on infeed and the weight of the filled bottle on outfeed.

Powder dosing machines designed to handle plugs and plungers produced in “monobloc” versions with an integrated plunging system. All parts in contact with the product are manufactured in FDA- approved material and are supplied together with the relevant certificates. They have been designed in such a way to make them easy to remove, easy to inspect and quickly cleanable. The Siempharma dosing and plunging machines feature a Dual Chamber System configuration; they can be equipped with a single or double dosing head and with plugging heads able to handle this particular packaging system (plunger + plug). The machines have been designed in compliance with GMP standards and particular attention has been paid to ergonomics in order to maintain visual control of all stages of the process and to ensure easy access to all parts of the unit. The dosage is performed by means of a volumetric screw feeder made of AISI 316L, with a servomotor ensuring perfect control and possibility to set speed and time, via operator panel, according to the product type and the requested speed, thus ensuring high accuracy of dosage. The dosage parameters can be set, saved and stored via the operator panel to be made immediately available in the event of a production change; this ensures the standardization of the process resulting in the achievement of high levels of efficiency and quality.
Machinery List
POWDER DOSING-PLUGGING MONOBLOC DS-1/2 MINERVAPPING MONOBLOC CM-50 ARGUS>>

Siempharma offers complete lines for injectable products in pre- filled syringes and vials, from the washing process of the primary container to resting the final packed product on the pallet. Siempharma combines its experience in machine production for sterile injectable products with the advanced technological robotic solutions. This winning combination results in the development of new solutions aimed at improving Laminar Air Flow uniformity and the cleanability of the most critical areas of machinery in the aseptic process.

Technologies for filling, statistical or 100% weight check, capping and aluminium seals for vials for injectable use, containing liquid or freeze-dried products. The construction principles of these machines offer maximum efficiency of laminar flow; they guarantee perfect, safe accessibility to all critical zones during operation; they allow routine maintenance to be carried out from outside the filling area; in addition, they are designed for installation in containment cabinets such as open RABS, closed RABS and isolators of the ISOL-AIR series produced by Siempharma.

CONTINUOUS MOTION ROTARY VIAL FILLING-STOPPERING MACHINE RFS-100/200 HYGEIA>

CONTINUOUS MOTION ROTARY STOPPERING-CAPPING MACHINE RSC-100/200 LADON>

CONTINUOUS MOTION ROTARY CAPPING MACHINE RC-100/200 LADON>

AUTOMATIC LINEAR FILLING-STOPPERING MACHINE LFS-8 PHOEBUS>

AUTOMATIC CAPPING MACHINE AS-2 HYGEIA>
Technologies for assembly and labelling of syringes comprise a vast range of solutions for the handling of glass and plastic syringes, including plungering, labelling of the syringe body, assembly of the Backstop, insertion of Safety Devices and, if required, labelling of the Safety Devices themselves. Robust, reliable and flexible in terms of line layout, these machines are pre-arranged for traditional connection in line with conveyors of the NTS and NAS series, and with “No Glass to Glass Contact” versions.
Machines for filling and stoppering of nested single-use syringes are characterised by superbly compact and versatile design. All the main operations – from Tub opening to sampling and outfeed of filled syringes – are managed by brushless motors and SCARA robots designed entirely in-house by Siempharma. While offering extremely fast filling speeds of up to 600 pieces per minute, and the possibility to carry out in-line 100% weight checking, these technologies also offer a superb level of flexibility that also enables them to work with cartridges and RTU (Ready To Use) vials supplied in Nests/Tubs or, in the case of vials only, in larger Nested-Trays.
Syringe handling units can feed, collect or sort syringes taken from Nests/Tubs or Rondo Trays. The technologies used, based on brushless motors and robots designed and constructed entirely in-house by Siempharma, guarantee gentle handling of syringes or Safety Devices, both for in-line connections with traditional conveyors of the NTS and NAS series, and for connections of the “No Glass to Glass Contact” type.